{"id":513,"date":"2021-05-25T05:59:52","date_gmt":"2021-05-25T05:59:52","guid":{"rendered":"http:\/\/www.hvrmagnet.com\/blog\/?p=513"},"modified":"2021-09-27T08:36:28","modified_gmt":"2021-09-27T08:36:28","slug":"the-minimum-thickness-of-steel-for-lifting-magnet","status":"publish","type":"post","link":"https:\/\/www.hvrmagnet.com\/blog\/the-minimum-thickness-of-steel-for-lifting-magnet\/","title":{"rendered":"The Minimum Thickness of Steel for Lifting Magnet Manufactured by HVR MAG"},"content":{"rendered":"<p>When choosing a proper magnetic lifting device, some steel workers may have such queries like, what&#8217;s the minimum thickness of steel that <strong>lifting magnet<\/strong> can lift? Well, here, <a href=\"https:\/\/www.hvrmagnet.com\/\"><strong>magnetic lifter manufacturer<\/strong><\/a> <strong><span style=\"color: #3366ff;\">HVR MAG<\/span><\/strong>, will answer the question from different point of views.<\/p>\n<p><a href=\"https:\/\/www.hvrmagnet.com\/category\/electro-permanent-lifting-magnets-1.html\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-515\" src=\"http:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/diagram.jpg\" alt=\"Holding Power of Lifting Magnet Affected by Steel Thickness | HVR MAG\" width=\"490\" height=\"224\" srcset=\"https:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/diagram.jpg 490w, https:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/diagram-300x137.jpg 300w\" sizes=\"(max-width: 490px) 100vw, 490px\" \/><\/a><\/p>\n<p>First of all, we need to know that the lifting capacity of lift magnet could vary depending on the load(material) thickness, surface condition, shape and material of object to be handled.<\/p>\n<p>The magnetic flux of magnetic lifters requires a minimum material thickness. If the workpiece does not reach this minimum thickness, the holding power(lifting force) is smaller. For larger lifting benefits greater material thicknesses are required.<\/p>\n<p>The thickest steel plate\/sheet that HVR MAG&#8217;s <a href=\"https:\/\/www.hvrmagnet.com\/category\/electro-permanent-lifting-magnets-1.html\"><strong>magnetic lifting system<\/strong><\/a> had handled is 1.5mm. The HM5 Series, <a href=\"https:\/\/www.hvrmagnet.com\/product\/lifting-magnets-for-cutting-systems-25.html\">cutting table magnets<\/a> for fast and efficient loading &amp; unloading of sheet on any type of cutting machines (plasma, oxyacetylene, laser), specially developed to remove cut pieces, including residual material, from the cutting table in one movement.<a href=\"https:\/\/www.hvrmagnet.com\/product\/lifting-magnets-for-cutting-systems-25.html\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-516\" src=\"http:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/HM5.jpg\" alt=\"Model chart of HM5 cutting table magnets for lifting steel plate | HVR MAG\" width=\"1482\" height=\"141\" srcset=\"https:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/HM5.jpg 1482w, https:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/HM5-300x29.jpg 300w, https:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/HM5-1024x97.jpg 1024w, https:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/HM5-768x73.jpg 768w, https:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/HM5-1200x114.jpg 1200w\" sizes=\"(max-width: 1482px) 100vw, 1482px\" \/><\/a><\/p>\n<p>HM3 Series <a href=\"https:\/\/www.hvrmagnet.com\/product\/thin-steel-plate-lifting-magnets-23.html\">Thin Steel Plate Lifting Magnet<\/a> is designed for lifting thin steel plate with a minimum thickness of 3 mm.<a href=\"https:\/\/www.hvrmagnet.com\/product\/thin-steel-plate-lifting-magnets-23.html\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-517\" src=\"http:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/HM3.jpg\" alt=\"Model chart of HM3 Series Lifting Magnet for Lifting Steel | HVR MAG\" width=\"1651\" height=\"376\" srcset=\"https:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/HM3.jpg 1651w, https:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/HM3-300x68.jpg 300w, https:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/HM3-1024x233.jpg 1024w, https:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/HM3-768x175.jpg 768w, https:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/HM3-1536x350.jpg 1536w, https:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/HM3-1200x273.jpg 1200w\" sizes=\"(max-width: 1651px) 100vw, 1651px\" \/><\/a><\/p>\n<p>HBEPP Series <a href=\"https:\/\/www.hvrmagnet.com\/product\/electro-permanent-magnetic-lifting-beam-with-battery-supply-for-single-steel-plate-32.html\">battery powered\/operated lifting magnet<\/a>, for steel lifting operation in areas where power supply is unavailable, the minimum thickness of plate is 2mm.<\/p>\n<p><a href=\"https:\/\/www.hvrmagnet.com\/product\/electro-permanent-magnetic-lifting-beam-with-battery-supply-for-single-steel-plate-32.html\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-518\" src=\"http:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/HBEPP.jpg\" alt=\"Model chart of HBEPP Series Battery Lifting Magnet | HVR MAG\" width=\"1689\" height=\"332\" srcset=\"https:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/HBEPP.jpg 1689w, https:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/HBEPP-300x59.jpg 300w, https:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/HBEPP-1024x201.jpg 1024w, https:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/HBEPP-768x151.jpg 768w, https:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/HBEPP-1536x302.jpg 1536w, https:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/HBEPP-1200x236.jpg 1200w\" sizes=\"(max-width: 1689px) 100vw, 1689px\" \/><\/a><\/p>\n<p>What needs to be pointed out is that the minimum thickness of steel mentioned is for uniformly shaped steel material. For unevenly structured steel, the lifting capacity of lifting magnet shall be specifically designed and engineered per your material specification and handling requirement. <span style=\"color: #3366ff;\"><strong>HVR MAG<\/strong><\/span> provides customized magnetic lifting solution for various steel industries.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>When choosing a proper magneti&#8230; <\/p>\n","protected":false},"author":1,"featured_media":515,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[6],"tags":[239,240],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v20.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>The Minimum Thickness of Steel for Lifting Magnet | HVR MAG<\/title>\n<meta name=\"description\" content=\"Explanations on the minimum thickness of steel that lifting magnet can lift, for better choosing of a proper magnetic lifting device.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.hvrmagnet.com\/blog\/the-minimum-thickness-of-steel-for-lifting-magnet\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"The Minimum Thickness of Steel for Lifting Magnet | HVR MAG\" \/>\n<meta property=\"og:description\" content=\"Explanations on the minimum thickness of steel that lifting magnet can lift, for better choosing of a proper magnetic lifting device.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.hvrmagnet.com\/blog\/the-minimum-thickness-of-steel-for-lifting-magnet\/\" \/>\n<meta property=\"og:site_name\" content=\"HVR MAG\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/davisn.ren.3\" \/>\n<meta property=\"article:published_time\" content=\"2021-05-25T05:59:52+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-09-27T08:36:28+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/diagram.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"490\" \/>\n\t<meta property=\"og:image:height\" content=\"224\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"hvrmag\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u4f5c\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"hvrmag\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data2\" content=\"1\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.hvrmagnet.com\/blog\/the-minimum-thickness-of-steel-for-lifting-magnet\/\",\"url\":\"https:\/\/www.hvrmagnet.com\/blog\/the-minimum-thickness-of-steel-for-lifting-magnet\/\",\"name\":\"The Minimum Thickness of Steel for Lifting Magnet | HVR MAG\",\"isPartOf\":{\"@id\":\"https:\/\/www.hvrmagnet.com\/blog\/#website\"},\"datePublished\":\"2021-05-25T05:59:52+00:00\",\"dateModified\":\"2021-09-27T08:36:28+00:00\",\"author\":{\"@id\":\"https:\/\/www.hvrmagnet.com\/blog\/#\/schema\/person\/79a5d157f1142d8a7e821d01c5cf5dec\"},\"description\":\"Explanations on the minimum thickness of steel that lifting magnet can lift, for better choosing of a proper magnetic lifting device.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.hvrmagnet.com\/blog\/the-minimum-thickness-of-steel-for-lifting-magnet\/#breadcrumb\"},\"inLanguage\":\"zh-CN\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.hvrmagnet.com\/blog\/the-minimum-thickness-of-steel-for-lifting-magnet\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.hvrmagnet.com\/blog\/the-minimum-thickness-of-steel-for-lifting-magnet\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.hvrmagnet.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"The Minimum Thickness of Steel for Lifting Magnet Manufactured by HVR MAG\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.hvrmagnet.com\/blog\/#website\",\"url\":\"https:\/\/www.hvrmagnet.com\/blog\/\",\"name\":\"HVR MAG\",\"description\":\"Electro-permanent Magnet Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.hvrmagnet.com\/blog\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"zh-CN\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.hvrmagnet.com\/blog\/#\/schema\/person\/79a5d157f1142d8a7e821d01c5cf5dec\",\"name\":\"hvrmag\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-CN\",\"@id\":\"https:\/\/www.hvrmagnet.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/56d470a657b5695275f84d295cc6270d?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/56d470a657b5695275f84d295cc6270d?s=96&d=mm&r=g\",\"caption\":\"hvrmag\"},\"sameAs\":[\"http:\/\/en.hvrmagnet.com\/blog\"],\"url\":\"https:\/\/www.hvrmagnet.com\/blog\/author\/hvrmag\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"The Minimum Thickness of Steel for Lifting Magnet | HVR MAG","description":"Explanations on the minimum thickness of steel that lifting magnet can lift, for better choosing of a proper magnetic lifting device.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.hvrmagnet.com\/blog\/the-minimum-thickness-of-steel-for-lifting-magnet\/","og_locale":"zh_CN","og_type":"article","og_title":"The Minimum Thickness of Steel for Lifting Magnet | HVR MAG","og_description":"Explanations on the minimum thickness of steel that lifting magnet can lift, for better choosing of a proper magnetic lifting device.","og_url":"https:\/\/www.hvrmagnet.com\/blog\/the-minimum-thickness-of-steel-for-lifting-magnet\/","og_site_name":"HVR MAG","article_publisher":"https:\/\/www.facebook.com\/davisn.ren.3","article_published_time":"2021-05-25T05:59:52+00:00","article_modified_time":"2021-09-27T08:36:28+00:00","og_image":[{"width":490,"height":224,"url":"https:\/\/www.hvrmagnet.com\/blog\/wp-content\/uploads\/2021\/05\/diagram.jpg","type":"image\/jpeg"}],"author":"hvrmag","twitter_card":"summary_large_image","twitter_misc":{"\u4f5c\u8005":"hvrmag","\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"1\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.hvrmagnet.com\/blog\/the-minimum-thickness-of-steel-for-lifting-magnet\/","url":"https:\/\/www.hvrmagnet.com\/blog\/the-minimum-thickness-of-steel-for-lifting-magnet\/","name":"The Minimum Thickness of Steel for Lifting Magnet | HVR MAG","isPartOf":{"@id":"https:\/\/www.hvrmagnet.com\/blog\/#website"},"datePublished":"2021-05-25T05:59:52+00:00","dateModified":"2021-09-27T08:36:28+00:00","author":{"@id":"https:\/\/www.hvrmagnet.com\/blog\/#\/schema\/person\/79a5d157f1142d8a7e821d01c5cf5dec"},"description":"Explanations on the minimum thickness of steel that lifting magnet can lift, for better choosing of a proper magnetic lifting device.","breadcrumb":{"@id":"https:\/\/www.hvrmagnet.com\/blog\/the-minimum-thickness-of-steel-for-lifting-magnet\/#breadcrumb"},"inLanguage":"zh-CN","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.hvrmagnet.com\/blog\/the-minimum-thickness-of-steel-for-lifting-magnet\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.hvrmagnet.com\/blog\/the-minimum-thickness-of-steel-for-lifting-magnet\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.hvrmagnet.com\/blog\/"},{"@type":"ListItem","position":2,"name":"The Minimum Thickness of Steel for Lifting Magnet Manufactured by HVR MAG"}]},{"@type":"WebSite","@id":"https:\/\/www.hvrmagnet.com\/blog\/#website","url":"https:\/\/www.hvrmagnet.com\/blog\/","name":"HVR MAG","description":"Electro-permanent Magnet Manufacturer","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.hvrmagnet.com\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"zh-CN"},{"@type":"Person","@id":"https:\/\/www.hvrmagnet.com\/blog\/#\/schema\/person\/79a5d157f1142d8a7e821d01c5cf5dec","name":"hvrmag","image":{"@type":"ImageObject","inLanguage":"zh-CN","@id":"https:\/\/www.hvrmagnet.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/56d470a657b5695275f84d295cc6270d?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/56d470a657b5695275f84d295cc6270d?s=96&d=mm&r=g","caption":"hvrmag"},"sameAs":["http:\/\/en.hvrmagnet.com\/blog"],"url":"https:\/\/www.hvrmagnet.com\/blog\/author\/hvrmag\/"}]}},"_links":{"self":[{"href":"https:\/\/www.hvrmagnet.com\/blog\/wp-json\/wp\/v2\/posts\/513"}],"collection":[{"href":"https:\/\/www.hvrmagnet.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hvrmagnet.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hvrmagnet.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hvrmagnet.com\/blog\/wp-json\/wp\/v2\/comments?post=513"}],"version-history":[{"count":0,"href":"https:\/\/www.hvrmagnet.com\/blog\/wp-json\/wp\/v2\/posts\/513\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hvrmagnet.com\/blog\/wp-json\/wp\/v2\/media\/515"}],"wp:attachment":[{"href":"https:\/\/www.hvrmagnet.com\/blog\/wp-json\/wp\/v2\/media?parent=513"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hvrmagnet.com\/blog\/wp-json\/wp\/v2\/categories?post=513"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hvrmagnet.com\/blog\/wp-json\/wp\/v2\/tags?post=513"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}